SENS Advanced Mass Spectrometry HORIBA
Elemental optical emission analysis / ICP-OES HORIBA ULTIMA Expert
ICP-OES

HORIBA ULTIMA Expert ICP-OES

High-resolution ICP-OES for rare earths, waters, materials and laboratories facing complex matrices, spectral interferences and demanding detection targets.

1 m focal length
120–800 nm spectral coverage
< 5 pm resolution 120–320 nm
ICP-OES HORIBA ULTIMATE Spectrometer Expert
ICP-OES HORIBA ULTIMATE Spectrometer Expert
Summary

ULTIMA Expert is the high-resolution ICP-OES route of SENS for rare earths, waters, effluents, materials and methods in which near lines and spectral interferences need to be strictly controlled.

Solution overview

Spectral resolution for complex methods

The 1-metre Jobin Yvon optical architecture, High-density holographic grating and 120-800 nm coverage offer freedom to select analytical lines and develop methods in demanding matrices.

Rare earth elements Water and effluents Materials Catalisadores Industrial solutions

Why does the resolution matter?

In line-rich spectra, nearby signals can compromise identification and quantification. High resolution helps separate these signals, expand wavelength options and build more robust methods.

This is especially relevant for rare earths and materials of complex composition.

Priority applications

Applications for HORIBA ICP-OES

The platform serves different sectors, with emphasis on applications that require resolution, wide choice of lines and adaptation to various matrices.

Key application
01

Rare earth elements

Quantification of 17 Rare earth elements in digests and solutions, including recycled magnet materials, with control of nearby lines and interferences.

Key application
02

Water and effluents

Monitoring of metals, nutrients and contaminants in drinking water, natural waters, effluents and environmental digests.

Key application
03

Materials

Raw materials, solubilized alloys, ceramics, glass, catalysts and process solutions after compatible preparation.

Additional application
04

Oils and fuels

Wear metals, additives, contaminants and product control with proper introduction system to the organic matrix.

Key features

Resources supporting the method

Performance does not depend on a single number. Optical, plasma observation, sample introduction and software need to function as a set.

One-meter optical system

It favors the separation of nearby spectral lines and the development of methods in complex matrices.

High-density holographic grating

It contributes to high resolution throughout broad spectral coverage.

Sheath Gas

It assists plasma stability and tolerance to matrices with higher dissolved solid content, according to configuration and method.

Total Plasma View

Extends the observation flexibility to reconcile sensitivity, analytical range and robustness.

Reference data

Technical view

Initial triage information. The final configuration should consider elements, matrix, preparation, concentration range, throughput and accessories.

Technique ICP-OES with argon plasma
Optical Focal distance of 1 m and holographic network
Coverage 120 a 800 nm
Resolution Less than 5 pm between 120 and 320 nm
Observation Radial e Total Plasma View
Samples Solutions, digests and previously solubilized materials
Positioning in hub

Complementary to MICAP-OES

The two platforms cover distinct and complementary needs within optical emission.

When this route tends to be indicated

Prioritise the evaluation of ULTIMA Expert for rare earths, waters, materials, complex matrices and methods that require greater spectral flexibility. For soils and certain mining routines, the MICAP-OES page shows another complementary route.

Meet MICAP-OES
Frequently Asked Questions

Technical information

Why is ULTRA Expert suitable for rare earths?

High-resolution optics help separate nearby lines and reduce the impact of frequent spectral interference on complex rare earth matrices.

Does the equipment serve water and effluent?

Yes. The ICP-OES HORIBA can be configured for multi-element analysis of water and effluents, considering method, preparation, calibration, bands and appropriate accessories.

Does ICP-OES analyze solid materials directly?

Not in conventional configuration. Solid materials usually require digestion, fusion followed by dissolution or other compatible preparation.

Can the ULTIMA Expert handle high dissolved-solids content?

Radial observation and the Sheath Gas feature help extend the tolerance to matrices with higher dissolved solid content, always according to configuration and method.

Application assessment

Inform the matrix, elements, expected ranges, preparation and volume of samples. SENS specifies the applicable ICP-OES configuration.