IonPlus AMS

IonPlus systems for accelerator mass spectrometry (AMS).

Platforms for carbon-14 measurement and multi-isotopic applications, with sample preparation, automation, control software and SENS support for the AMS laboratories implementation in Brazil.

IonPlus MICADAS, AMS system dedicated to carbon-14 measurement
MICADAS
IonPlus LEA, compact carbon-14 accelerator mass spectrometer
LEA
IonPlus MILEA, low-energy multi-isotopic AMS system
MILEA

From sample preparation to final data: an AMS architecture designed for routine, research and high reliability.

14C Radiocarbon for archeology, environment, materials, forensics and biomedicine.
Multi 10Be, 26Al, 41Ca, 129I, U, Pu and actinides in systems MILEA.
Automation GIS, ACS and LMP for solid samples, gas and routine flows.
Compacto Low infrastructure requirement on 14C platforms.

choice by need

Selecting an AMS system

The IonPlus line allows you to organize the choice by application: 14C dedicated, ultra-high precision, lower infrastructure or multi-isotopes for geology, environment and anthropogenic radionuclides.

Initial Recommendation

MICADAS for 14C laboratories with maximum technical maturity.

Platform dedicated to 14C, compact for category, with low consumption, measurement stability and broad GIS integration for solid samples, liquid and gaseous.

Platform
MICADAS
Foco
14C, high precision, routine and research
View Platform +

AMS Platforms

Four paths to different levels of application.

IonPlus organizes the line between systems dedicated to 14C and multi-isotope systems low power. The choice depends on the isotopes, the infrastructure available, the volume of samples and the precision requirement.

01
IonPlus MILEA

Multi-isotope low-energy AMS

MILEA

Multi-isotope system for wide AMS applications, focusing on 129I and actinides.

It combines MICADAS concepts with high energy spectrometry inspired by TANDY, focused on 10Be, 14C, 26Al, 41Ca, 129I, U, Pu and other actinides.

  • 300 kV rated voltage.
  • Approximate dimensions: 3,5 m x 7 m.
  • For laboratories that need to go beyond the dedicated 14C.
Detalhes IonPlus +
02
IonPlus MILEA light

MILEA light

MILEA light

Simpler and compact alternative for 10Be, 14C and 26Al.

Developed for demanding applications in geology and Earth system sciences, preserving concepts of MILEA architecture in a reduced configuration.

  • 300 kV rated voltage.
  • 10Be, 14C, 26Al and 41Ca as an option.
  • Approximate dimensions: 3.0 m x 4.8 m.
Detalhes IonPlus +
03
IonPlus MICADAS

Mini Carbon Dating System

MICADAS

Consecrated platform for 14C AMS, high precision and routine.

14C system with 200 kV accelerator, random sample exchange, low consumption, air cooling and GIS integration for gas samples.

  • Accuracy of 2 per thousand, with 1 per thousand possible.
  • Approximate dimensions: 3.2 m x 2.6 m.
  • Typical consumption less than 2,5 kW.
Detalhes IonPlus +
04
IonPlus LEA

Low Energy AMS

LEA

New compact generation for 14C AMS with low installation requirement.

Based on the concepts of MICADAS, the LEA significantly reduces occupation physics without compromising performance for applications dedicated to 14C.

  • 60 kV acceleration platform isolated to void.
  • Approximate dimensions: 2.6 m x 1.8 m.
  • Air-cooled system with no SF6 required.
Detalhes IonPlus +

Technical comparison

Summary of available configurations.

The values below have been organized from the IonPlus overview and serve as as the initial configuration guide.

Platform Rated voltage Isotopes Intended use Dimensions Consumption / cooling
MILEA 300 kV 10Be, 14C, 26Al, 41Ca, 129I, U, Pu and actinides Multi-isotopic AMS applications, focusing on 129I and actinides 3,5 m x 7 m up to 60 kW / water
MILEA light 300 kV 10Be, 14C and 26Al; optional 41Ca Geology and system science Earth. 3,0 m x 4,8 m up to 60 kW / water
MICADAS 200 kV 14C 14C applications, including high precision 3,2 m x 2,6 m < 2,5 kW / ar
LEA 50-60 kV 14C 14C over 2 permil and dedicated gas applications 2,6 m x 1,8 m < 2,5 kW / ar

Interfaces and preparation

An AMS system includes the accelerator, interfaces and sample preparation.

The IonPlus package becomes especially strong when the AMS platform and connected to gas interfaces, elemental analyzers, IRMS and automated systems of Ready. This helps turn the line into a lab solution, not just in isolated equipment.

01

GIS

Gas interface for automated 14C measurements, including CO2 in ampoules, gas samples and couplings to instruments that generate CO2.

02

EA + GIS + AMS

Flux for solid and liquid samples with the possibility of rapid screening, high throughput and measurement time adjustment as needed.

03

EA + IRMS + GIS

Combines 14C with stable online isotopic information such as delta 13C and delta 15N, where the application requires origin, mixture or traceability.

04

Carbonates and DIC

Solution for acidification, preparation and measurement of small carbonates, sediments, water and dissolved inorganic carbon.

05

ACS and LMP

Software control, autotuning, workflows, diagnosis, data reduction and laboratory management for routine AMS.

06

Training and acceptance testing

IonPlus works with complete packages, including training and testing acceptance of factory and field for laboratory deployment.

Applications

IonPlus application areas.

The product line serves laboratories working with radiocarbon, modern-versus-fossil carbon tracing, geochronology, microtracers and long-lived radionuclides.

01

Archaeology and paleoclimate

14C date with focus on precision, reproducibility and reliability for historical, archaeological and calibration series samples.

02

Environmental sciences

Studies of carbon cycle, biogeochemical, modern carbon/fossil and small samples in complex environmental matrices.

03

Marine research

Carbonates, foraminifera, sediments, IHD and carbon studies in water with automated preparation and measurement AMS.

04

Materials, fuels and bio-based materials

Certification of biogenic content, differentiation between fossil and renewable carbon and simultaneous measurement of 14C and delta 13C.

05

Biomedicine and microtracers

Applications that require high sensitivity, carbon quantification and high analytical performance in small sample quantities studies.

06

Geology and anthropogenic radionuclides

10Be, 26Al, 41Ca, 129I, U, Pu and actinides for exposure, denudation, environmental monitoring and contaminants tracking.

Frequently Asked Questions

Questions about IonPlus and AMS.

Information to compare platforms and understand where the technique is Fits before setting up the lab.

What is accelerator mass spectrometry (AMS)?

AMS is a high sensitivity technique that separates and quantifies isotopes rare, such as carbon-14, by ion acceleration and suppression of molecular interference.

Which IonPlus equipment is suitable for carbon-14?

MICADAS and LEA are platforms dedicated to carbon-14. MICADAS answers consolidated routines and high precision applications; LEA prioritizes lower physical occupation and low infrastructure requirement.

Which IonPlus system measures multiple isotopes?

MILEA is the most comprehensive multi-isotopic platform. MILEA light offers a reduced configuration to 10Be, 14C and 26Al, with 41Ca optional.

Which samples can be analyzed by carbon-14 AMS?

With adequate preparation and interfaces, samples can be analyzed solid, liquid and gaseous, including archaeological materials, fuels, bio-based products, carbonates, sediments, water and CO2.

Materials

Technical downloads and configuration resources.

IonPlus official links give access to technical documentation and available materials. See the manufacturer's page for updated versions.

PDF

AMS Overview

Comparative of MILEA, MILEA light, MICADAS and LEA on a page.

Download Overview +
Product

IonPlus AMS

Official page with comparison of IonPlus AMS platforms.

See official page +
Application

Interfaces

Examples of couplings with GIS, EA, IRMS, carbonates and CO2 generating instruments.

View interfaces +

SENS + IonPlus

Laboratory projects AMS in Brazil

SENS supports configuration definition, application discussion, infrastructure, sample preparation and integration of the IonPlus solution to the technical objective of the laboratory.